Mineral insulated cables for RTDs have inner conductors of copper, copper-nickel alloys, nickel, nickel-chromium, or nickel-plated copper.
Sheath Diameter (mm) | Number of Core | Nominal Wall Thickness (mm) | Element Diameter (mm) | Insulation Resistance (MΏ) | Sheath Material | Conductor Type | Insulation |
---|---|---|---|---|---|---|---|
2.00 | 2 Core & 3 Core | ≥ 0.20 | ≥ 0.30 | ≥ 100 MΏ | SS316L SS321 SS310 SS446 SS304 Inconel 600 Inconel 601 and others | Copper Nickel Nickel-Copper Alloy and others | MgO
|
2.50 | ≥ 0.25 | ≥ 0.38 | |||||
3.00 | ≥ 0.30 | ≥ 0.45 | |||||
4.50 | ≥ 0.45 | ≥ 0.68 | |||||
6.00 | ≥ 0.60 | ≥ 0.90 | |||||
6.40 | ≥ 0.64 | ≥ 0.96 | |||||
8.00 | ≥ 0.80 | ≥ 1.20 | |||||
9.50 | ≥ 0.95 | ≥ 1.43 | |||||
10.00 | ≥ 1.00 | ≥ 1.50 | |||||
2.00 | 4 core | ≥ 0.20 | ≥0.24 | ≥ 100 MΏ | SS316L SS321 SS310 SS446 SS304 Inconel 600 Inconel 601 and others | Copper Nickel Nickel-Copper Alloy and others | MgO
|
2.50 | ≥ 0.25 | ≥ 0.30 | |||||
3.00 | ≥ 0.30 | ≥0.36 | |||||
4.50 | ≥ 0.45 | ≥ 0.54 | |||||
6.00 | ≥ 0.60 | ≥ 0.72 | |||||
6.40 | ≥ 0.64 | ≥ 0.77 | |||||
8.00 | ≥ 0.80 | ≥0.96 | |||||
9.50 | ≥ 0.95 | ≥ 1.14 | |||||
10.00 | ≥ 1.00 | ≥ 1.20 | |||||
3.00 | 6 core | ≥ 0.30 | ≥ 0.30 | ≥ 100 MΏ | SS316L SS321 SS310 SS446 SS304 Inconel 600 Inconel 601 and others | Copper
| MgO
|
4.50 | ≥ 0.45 | ≥ 0.45 | |||||
6.00 | ≥ 0.60 | ≥ 0.60 | |||||
6.40 | ≥ 0.64 | ≥ 0.64 | |||||
8.00 | ≥ 0.80 | ≥ 0.80 | |||||
9.50 | ≥ 0.95 | ≥ 0.95 | |||||
10.00 | ≥ 1.00 | ≥ 1.00 | |||||
|
|
| |||||
6.00 | 8 core | ≥ 0.60 | ≥ 0.60 | ≥ 100 MΏ | SS316L SS321 SS310 SS446 SS304 Inconel 600 Inconel 601 and others | Copper
| MgO
|
6.40 | ≥ 0.64 | ≥ 0.64 | |||||
8.00 | ≥ 0.80 | ≥ 0.80 | |||||
9.50 | ≥ 0.95 | ≥ 0.95 | |||||
10.00 | ≥ 1.00 | ≥ 1.00 |
Ordering Example
80-4Cu316 RTD MI Cable: 8.0 mm OD, 4 Cores, Copper Conductor, SS316L Sheath
60-6NiCu600 RTD MI Cable: 8.0 mm OD, 4 Cores, Nickel-Copper Alloy Conductor (Constantan), Inconel 600 Sheath.