Mineral Insulated Copper cable은 전기 케이블 등급에 속합니다.
Details | Standard Follow | Description |
---|---|---|
MI Power Cable | IEC/EN 60702 Part 1 | Mineral Insulated Copper sheathed Cable with Copper Conductor |
Copper Conductor | IEC 60228 for Class 1 | Copper (>99.9 %) |
Insulation | IEC/EN 60702 Part 1 | MgO (>99.4 % Pure) |
Metallic Sheath | ASTM B75 Specification | Seamless Copper Tube (99.9%) |
Insulation Resistance | IEC/EN 60702 Part 1 | >1000 MΏ for above 100 Mtr coil |
Testing | ||
A) Routine Test | IEC/EN 60702 Part 1 | Conductor Resistance, Insulation Resistance, Sheath And Insulation Integrity, Diameter & ovality |
B) Type Test | IEC/EN 60702 Part 1 | Voltage Test, Resistance of Copper Sheath, Insulation Thickness, Sheath Thickness, Bending test, Flattening test, Fire Resistance |
Technical Specifications for MI Copper Cable